Read data from the epcs/epcq/epcq-l device – Altera Active Serial Memory Interface User Manual

Page 22

Advertising
background image

Related Information

Serial Configuration Devices Datasheet

For more information about the block protection level for EPCQ devices. Every devices have different

block protection level.

EPCQ-L Serial Configuration Devices Datasheet

For more information about the block protection level for EPCQ-L devices. Every devices have

different block protection level.

Read Data from the EPCS/EPCQ/EPCQ-L Device

Use the

read

signal to instruct the IP core to read data from the EPCS/EPCQ/EPCQ-L device. The Altera

ASMI Parallel IP core supports two types of read data operation: multiple-byte and single-byte read.

Figure 6: Reading Multiple-Byte

This figure shows an example of the latency when the Altera ASMI Parallel IP core is executing multiple-

byte read command. The latency shown does not correctly indicate the true processing time. It shows the

command only.

Figure 7: Reading Single-Byte

This figure shows an example of single-byte read command. The latency shown does not correctly

indicate the true processing time. It shows the command only.

The IP core registers the

read

signal on the rising edge of the

clkin

signal. After the IP core

receives the read command, it asserts the

busy

signal to indicate that the read command is in

progress.
Ensure that the read address appears on the

addr[23..0]

signal before asserting the

read

signal.

The

rden

signal must also be asserted to enable the read operation.

22

Read Data from the EPCS/EPCQ/EPCQ-L Device

UG-ALT1005

2014.12.15

Altera Corporation

Altera ASMI Parallel IP Core User Guide

Send Feedback

Advertising