Chapter 4: Development Board Setup

4–3

Factory Default Switch and Jumper Settings

November 2012

Altera Corporation

Arria V GT FPGA Development Kit

User Guide

To restore the switches to their factory default settings, perform the following steps:

1. Set DIP switch bank (SW4) to match

Table 4–1

and

Figure 4–2

.

2. Set DIP switch bank (SW5) to match

Table 4–2

and

Figure 4–2

.

Table 4–1. SW4 FPGA2 MSEL Dip Switch Settings

(1)

Switch

Board

Label

Function

Default

Position

1

FPGA2_MSEL[1]

Switch 1 has the following options:

When ON, a logic 0 is selected.

When OFF, a logic 1 is selected.

ON

2

FPGA2_MSEL[2]

Switch 2 has the following options:

When ON, a logic 0 is selected.

When OFF, a logic 1 is selected.

OFF

3

ON

4

FPGA2_MSEL[4]

Switch 4 has the following options:

When ON, a logic 0 is selected.

When OFF, a logic 1 is selected.

OFF

Note to:

Table 4–1

(1) Ensure that all MSEL setting are in a defined configuration scheme as shown in

Volume 2: Device Interfaces and

Integration

of the Arria V Device Handbook.

Table 4–2. SW5 Board Settings Dip Switch

Switch

Board

Label

Function

Default

Position

1

CLK_SEL

Switch 1 has the following options:

ON, (logical 0) = SMA input clock select.

OFF, (logical 1) = programmable oscillator clock select.

OFF

2

CLK_EN

Switch 2 has the following options:

ON, (logical 0) = on-board oscillator disable.

OFF, (logical 1) = on-board oscillator enable.

ON

3

Factory1

Switch 3 has the following options:

ON, (logical 0) = load the factory design for Arria V
FPGA 1 from flash at power up.

OFF, (logical 1) = load the user design for Arria V FPGA
1 from flash at power up.

ON

4

Factory2

Switch 4 is for factory test only.

OFF