Port (FPGA2)

The Port (FPGA2) control allows you to specify which interface to test

.

The following

port test is available:

SMA (GXB_R9)

(design run at 10 Gbps)

Bull’s Eye (GXB_L15)

(design run at 10 Gbps)

PMA Setting

The PMA Setting

button allows you to make changes to the PMA parameters that

affect the active transceiver interface. The following settings are available for analysis:

Serial Loopback

—Routes signals between the receiver and the transmitter. Enter

the following values to enable the serial loopbacks:

0

= high speed serial transceiver signals to loopback on the board

1

= serial loopback

2

= reverse serial loopback pre-CDR

4

= reverse serial loopback post-CDR

VOD

—Specifies the voltage output differential of the transmitter buffer.

Pre-emphasis tap

Pre

—Specifies the amount of pre-emphasis on the pre-tap of the transmitter

buffer.

First post

—Specifies the amount of pre-emphasis on the first post tap of the

transmitter buffer.

Second post

—Specifies the amount of pre-emphasis on the second post tap of

the transmitter buffer.

Equalizer

—Specifies the setting for the receiver equalizer.

DC gain

—Specifies the DC portion of the receiver equalizer.

Data Type

The Data type control specifies the type of data contained in the transactions. The
following data types are available for analysis:

PRBS7

—Selects pseudo-random 7-bit sequences.

PRBS15

—Selects pseudo-random 15-bit sequences.

PRBS23

—Selects pseudo-random 23-bit sequences.

PRBS31

—Selects pseudo-random 31-bit sequences.

HF1

—highest frequency divide-by-2 data pattern 10101010.

HF2

—next highest frequency divide-by-4 data pattern 1100110011001100.

HF3

—second lowest frequency divide-by-8 data pattern 1111000011110000.

LF

—lowest frequency divide-by-32 data pattern.

1

Settings HF1, HF2, HF3, LF are for transmit observation only.