Operating conditions, Operating conditions –4 – Altera EthernetBlaster II User Manual

Page 28

Advertising
background image

3–4

Chapter 3: EthernetBlaster II Communications Cable Specifications

Operating Conditions

EthernetBlaster II Communications Cable User Guide

January 2014

Altera Corporation

Operating Conditions

Table 3–3

through

Table 3–5

list the maximum ratings, recommended operating

conditions, and DC operating conditions for the EthernetBlaster II communication
cable.

Table 3–3

lists the EthernetBlaster II cable absolute maximum ratings.

Table 3–4

lists the EthernetBlaster II Cable recommended operating conditions.

Table 3–5

lists the EthernetBlaster II Cable DC operating conditions.

Table 3–3. EthernetBlaster II Cable Absolute Maximum Ratings

Symbol

Parameter

Conditions

Min

Max

Unit

V

CC(TARGET)

Target supply voltage

With respect to ground

–0.3

5.5

V

V

CC(SYS)

System supply voltage

With respect to ground

36.0

V

I

I

Input current

TDO

or

dataout

–10.0

10.0

mA

I

o

Output current

TCK

,

TMS

,

TDI

,

nCS

,

nCE

–10.0

10.0

mA

Table 3–4. EthernetBlaster II Cable Recommended Operating Conditions

Symbol

Parameter

Conditions

Min

Max

Unit

V

CC(TARGET)

Target supply voltage, 3.3-V operation

3.0

3.6

V

Target supply voltage, 2.5-V operation

2.375

2.625

V

Target supply voltage, 1.8-V operation

1.71

1.89

V

Target supply voltage, 1.5-V operation

1.43

1.57

V

Target supply voltage, 1.2-V operation

1.1

1.26

V

Table 3–5. EthernetBlaster II Cable DC Operating Conditions

(Part 1 of 2)

Symbol

Parameter

Conditions

Min

Max

Unit

V

IH

High-level input voltage

V

CC(TARGET)

= 3.3 V

2.0

V

High-level input voltage

V

CC(TARGET)

= 2.5 V

1.6

V

High-level input voltage

V

CC(TARGET)

= 1.8 V

0.65 * V

CC(TARGET)

V

High-level input voltage

V

CC(TARGET)

= 1.5 V

0.65 * V

CC(TARGET)

V

High-level input voltage

V

CC(TARGET)

= 1.2 V

0.9 * V

CC(TARGET)

V

V

IL

Low-level input voltage

V

CC(TARGET)

= 3.3 V

0.8

V

Low-level input voltage

V

CC(TARGET)

= 2.5 V

0.7

V

Low-level input voltage

V

CC(TARGET)

= 1.8 V

0.35 * V

CC(TARGET)

V

Low-level input voltage

V

CC(TARGET)

= 1.5 V

0.35 * V

CC(TARGET)

V

Low-level input voltage

V

CC(TARGET)

= 1.2 V

0.1 * V

CC(TARGET)

V

V

OH

3.3-V high-level output voltage

V

CC(TARGET)

= 3.0 V, IOH = 20 mA

V

CC(TARGET)

– 0.4

V

2.5-V high-level output voltage

V

CC(TARGET)

= 2.375 V, IOH = 20 mA

V

CC(TARGET)

– 0.4

V

1.8-V high-level output voltage

V

CC(TARGET)

= 1.71 V, IOH = 20 mA

V

CC(TARGET)

– 0.4

V

1.5-V high-level output voltage

V

CC(TARGET)

= 1.43 V, IOH = 20 mA

V

CC(TARGET)

– 0.4

V

1.2-V high-level output voltage

V

CC(TARGET)

= 1.14 V, IOH = 20 mA

V

CC(TARGET)

– 0.4

V