Sdi clocked audio input registers, Sdi clocked audio input registers -8 – Altera SDI Audio IP Cores User Manual

Page 39

Advertising
background image

Clock Status Register

To create a 48-kHz signal synchronous to the video clock,
you must detect whether a 1 or 1/1.001 video clock rate is
used. If you detect a 1/1.001 video clock rate, this field
returns high.

RO

74.17-MHz video clock

7

Channel Status RAM

Read accesses within the address range 10h to 3Fh to the
channel status RAM. This field returns the 24 bytes of
channel status for X channel starting at address 10h, and
the 24 bytes of channel status for Y channel starting at
address 28h.

WO

Channel status data

7:0

SDI Clocked Audio Input Registers

The following tables list the registers for the SDI Clocked Audio Input IP core.

Table 5-5: SDI Clocked Audio Input Register Map

Name

Bytes Offset

Channel 0 Register

00h

Channel 1 Register

01h

FIFO Status Register

02h

FIFO Reset Register

03h

Table 5-6: SDI Clocked Audio Input Registers

Description

Access

Name

Bit

Channel 0 Register

The user-defined channel number of audio channel 0.

RW

Channel 0

7:0

Channel 1 Register

The user-defined channel number of audio channel 1.

RW

Channel status RAM select

7:0

FIFO Status Register

This sticky bit reports the overflow of the clocked audio
input FIFO.

RO

Active channel

7:0

FIFO Reset Register

Reserved for future use.

WO

Unused

6:0

Resets the clocked audio FIFO.

WO

FIFO reset

7

SDI Audio IP Registers

Altera Corporation

Send Feedback

UG-SDI-AUD

SDI Clocked Audio Input Registers

5-8

2014.06.30