Maintenance

The menu entry Maintenance enables software updates, changing the IP address, changing the password,
restarting the module and erasing service data.

Important: If you stay on the maintenance page for more than 2.5 minutes, an automatic logout will occur
and you will have to repeat the login procedure.

3.6.1.

Updating firmware/software

New firmware can be installed under Firmware File and new software for the interface can be installed under
Software File.

Firmware and software updates are available at

www.axing.com

under Download.

The module will be automatically rebooted after an update. The set parameters will not be lost after an update.

3.6.2.

Changing the IP address

The IP address, network mask and the gateway can be changed in the menu entry Maintenance > System
Options
. The SAVE CHANGES button confirms and saves the changes.

When the IP address has been changed, the device will boot automatically and the new IP address will be
entered in the web browser. When complete, the enter password site will be displayed.

3.6.3.

Changing the password

The default password should be changed right after commissioning the module. The default password can be
changed in the menu entry Maintenance > Set New Password.

The default password is: Ramsen8262.

Any new password must be 8-10 characters (letters and/or digits) long.

After changing the password, the module must be rebooted.