2.1.1.

Power supply in the headend base unit

A certain number of modules including LNB can be supplied depending on the headend base unit.

SKS 4-00 with

SKZ 5-01 (10 A)

SKS 40-00* with

SKZ 5-01 (10 A)

SKS 40-00* with

SKZ 5-04

(2x10A)

SKS 8-00 with

SKZ 6-00 (18 A)

SKQ 40-0x
1.5 A + LNB current
consumption

4 4 4 8

SKQ 80-0x
3 A + LNB current
consumption

3 3 4 5

*Please note: The SKS 40-00 is supplied without power supply unit and remote control.

2.2.

Stand-alone operation of the SKQ 40-00 / 80-00

Before installing the SKQ 40-00 / 80-00, the power supply must be switched off.

To avoid dangerous overvoltages (danger: risk of fire/death), the module must be grounded according to EN
50083-1, EN 60728-11:2010. Use the grounding screw attached to the device.

For operation without a basic unit, the outputs of two modules must be combined with a distributor.

2.2.1.

Power supply in stand-alone operation

If the SKQ 40-00 / 80-00 is operated in stand-alone mode, the power supply is directly connected via the DC
power cord of the power supply unit. This requires a separate power supply unit SKZ 5-03. Additional units are
connected via the DC loop output. One SKZ 40-00 DC connection cable each is included in the scope of delivery
of the SKQ 40-00 / 80-00.