View memory results – Casella CEL CEL-62X User Manual

Page 16

Advertising
background image

Casella CEL Limited

16

H. VIEW MEMORY RESULTS (Refer to Figure 10)

This is where the results from completed measurements are stored. The Memory
Results are stored in a chronological order, with the latest measurement at the top of
the list.

MEMORY RESULTS

From the Menu screen, use the cursor keys to select the Memory Results icon (1).
Press Select (B) to access the memory.

Use the Up/Down cursors (C) to navigate the listed results. When a Memory Result
has been selected, press Select (B) to access the measurement.

This screen gives the operator the choice to view the selected memory result, or to
delete it. Use the left/right cursor keys (C) to select View and press Select (B).

The Results screen displays an overview of measurement data for the selected run.
This is read only. To see the specific results, press View (B).

Figure 10 View Memory Results (Sheet 1)

The Octave values (CEL-62XB and C models only) saved in the Memory Result are
displayed in a graphical format. Use cursor keys (C) to move the cursor (1) across
the graph. Each graph bar represents an octave band measured in Hz or KHz.

Use the up/down cursors keys (C) to toggle between parameters such as L

MAX

and

L

AEQ

(2).

To view the numerical results (CEL-62XB and C models only), press View (B).

On CEL-62XC models, use the up/down cursors (C) when viewing numerical results
to alter the frequencies viewed.

Press EXIT (A) to leave the Memory Results or VIEW (B) to cycle the Memory
Results screens again.

Note: On CEL-62XC models either 1/1 octave values or 1/3 octave values will be
displayed dependent on the setup at the time of measurement.

Advertising