Figure 92 – CIRCUTOR AFQ Series User Manual

Page 80

Advertising
background image

AFQ-4W

80 Instruction Manual

Figure 92: Unscrew the turbine fasteners


20.- Replace the turbine with the spare.

21.- Reinsert the pack into the cabinet.

22.- Fix the extractor hood.

23.- Connect the turbine power supply.

24.- Connect the R-S-T phases to the inverter bridge.

25.- Put the NTC probe cable back in the channel.

26.- Connect the NTC probe.

27.- Connect the IGBTs to the driver board and reinstall the driver board if

necessary.

Respect the R-S-T order of the connectors.

28.- Connect the DC bus busbar.

29.- Insert the top crossbar of the AFQ-4W cabinet.

30.- Connect the earth wire to the front panel metal plate of the AFQ-4W.

31.- Fit the protection board.

32.- Check that the turbine operates correctly.

Advertising