Installation procedures – Pinnacle Systems DR User Manual

Page 23

Advertising
background image

16

Installation Procedures

DIN-rail Controller Module

RS-232 Serial Port (optional)

Terminal Connector

1 +15VDC

out

2 Transmit
3 Receive
5 Ground
6 +15VDC

Out

8 +15VDC

out

9 Ground

Wiring

Table 5 is a sample of how to wire the Controller Module.
Certain features are not needed for many installations.
Read the sections in this manual describing each feature
to decide which feature(s) you may need.

WARNING: Both K1 and K2 Safety Output Relays
must be used to issue a “STOP” signal to your
hazardous machinery—either with two separate stop
circuits or both relays wired in series.

RS-485 Serial Port (optional)

Terminal Connector

1 +15VDC

out

2 tx/rx
3 tx/rx
5 Ground
6 +15VDC

Out

8 +15VDC

out

9 Ground

Tables 5a-f: Controller Module Wiring

b

c

a

Receiver Wire Colors

Terminal Connector

1

Green & Red

2

Black & Brown

3 Purple
4 White
5 Blue
6 Yellow
7 Orange
8 Shield

(bare)

Inputs / Outputs

Terminal Connector

1

Analog Output + side

2

Analog Output - side

3

Latching Relay Input (ground to reset)

4

Mute-Out Input (LS4 input)

5

Mute-Out (LS5 input)

6

Remote Key Switch Key #1 (black wire)

7

Remote Key Switch Key #2 (red wire)

8

ESTOP Button 2

9

+24VDC input to power optically coupled
inputs

10

Remote Blanking Indicator Output (ground
when on)

11

Remote Blocked Indicator Output (ground
when on)

12

Remote OK Indicator Output (ground when
on)

Power/Relays

Terminal Connector

1 +24VDC

Input

2

-24 VDC input

3 Earth

Ground

4

Safety Relay K1 N.O. (Red = open)

5

Safety Relay K1 N.O.

6

Safety Relay K2 N.O.

7

Safety Relay K2 N.O.

8

Auxiliary Relay K3 N.O.

9

Auxiliary Relay K3 Common

10

Auxiliary Relay K3 N.O.

11

Fault Relay K4 N.O. (open = fault)

12

Fault Relay K4 N.O.

13

External Relay Input + side

14

External Relay Input - side

15

ESTOP +24VDC (optional CINN +)

16

ESTOP Button 1 (optional CINN-)

d

e

f

Emitter Wire Colors

Terminal Connector

1 Shield

(bare)

2 Yellow
3

Orange & Blue

4 Purple
5 Black/White
6 Brown
7 Green
8 Red
9 Red/white
10 Gray
11 Black
12 White

13

Installation Procedures

DIN-rail Controller Module

Advertising