Commissioning

Name

Type

Description

Default value

• other values are not permissible;

TurnUPSOffWait

REG_DWORD

Maximum delay time in seconds for switching
off the UPS output voltage after initiating the
Windows shutdown. The permissible values
can differ from model to model (depending on
hardware).

180

BatteryReplaceNoti
fyEnable

REG_DWORD

Activates/deactivates the logging of the battery
change service interval warnings in the
Windows event log: UPS software v3.0.0.8
and higher.

0

BatteryReplaceNoti
fyWait

REG_DWORD

Delay time in months for the first battery
change warning. This element can adopt a
value of between 0 and 480 months. Other
values are not permissible. Implemented in the
UPS software v3.0.0.8 and higher.

60

Advanced Settings

KEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\UPS

Name

Type

Description

Default value

FirstMessageDelay

REG_DWORD

Delay time in seconds for the first power­
fail message to the user

5

MessageInterval

REG_DWORD

Delay time in seconds for further power­
fail messages to the user.

20

CX2100­09x4

67

Version 1.1