Continental Fireplaces CDVS600 User Manual

Page 20

Advertising
background image

20

W415-0791 / C / 04.18.12

Simple venting configuration

(only two 90° elbows)

See graph to determine the required vertical rise V

T

for the

required horizontal run H

T

.

REQUIRED

VERTICAL

RISE IN

INCHES V

T

HORIZONTAL VENT RUN PLUS OFFSET IN FEET H

T

For vent configurations requiring more than two 90° elbows, the following formulas apply:

Formula 1: H

T

< 3.5V

T

Formula 2: H

T

+ V

T

< 24.75 feet

Example:
V

1

= 4 FT

V

2

= 1.5 FT

V

T

= V

1

+ V

2

= 4 + 1.5 = 5.5 FT

H

1

= 2 FT

H

2

= 1 FT

H

3

= 1 FT

H

4

= 1.5 FT

H

R

= H

1

+ H

2

+ H

3

+ H

4

= 2 + 1 + 1 + 1.5 = 5.5 FT

H

O

= .03 (four 90° elbows + one 45° elbow - 90°)

= .03 (90 + 90 + 90 + 90 + 45 - 90) = 9.45 FT
H

T

= H

R

+ H

O

= 5.5 + 9.45 = 14.95 FT

H

T

+ V

T

= 14.95 + 5.5 = 20.45 FT

Formula 1:

H

T

< 3.5V

T

3.5V

T

= 3.5 x 5.5 = 19.25 FT

14.95

<

19.25

Formula 2:

H

T

+ V

T

< 24.75 FT

20.45 < 24.75

Since both formulas are met, this vent configuration is acceptable.

The shaded area within the lines represents acceptable

values for H

T

and H

T

90°

V

1

V

2

H

1

H

2

90°

90°

90°

H

3

(H

T

) > (V

T

)

50

100

150

0

2.5

5

7.5

10

12.5

15

17.5

20

147

12

66

1

3.5

19.25

16.3_2A