Warning, Maintenance, 0 maintenance – Continental Fireplaces CDVS600 User Manual

Page 46

Advertising
background image

46

W415-0791 / C / 04.18.12

CAUTION:

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper

and dangerous operation. Verify proper operation after servicing. This appliance and its venting system

should be inspected before use and at least annually by a qualifi ed service person. The appliance area must

be kept clear and free of combustible materials, gasoline or other fl ammable vapors and liquids. The fl ow of

combustion and ventilation air must not be obstructed.
A.

In order to properly clean the burner and pilot assembly, remove the logs, rocks and/or glass to

expose both assemblies.

B.

Keep the control compartment, media, burner, air shutter opening and the area surrounding the logs

clean by vacuuming or brushing, at least once a year.

C.

Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or

are not burning properly.

D.

Check to see that the pilot fl ame is large enough to engulf the fl ame sensor and/or thermocouple /

thermopile as well as reaches the burner.

E.

Replace the cleaned logs, rocks or glass. Failure to properly position the media may cause carboning

which can be distributed in the surrounding living area.

F.

Check to see that the main burner ignites completely on all openings when turned on. A 5 to 10

second total light-up period is satisfactory. If ignition takes longer, consult your local authorized dealer /

distributor.

G.

Check that the gasketing on the sides, top and bottom of the door is not broken or missing. Replace if

necessary.

H.

If for any reason the vent air intake system is disassembled, re-install and re-seal per the instructions

provided for the initial installation.

40.1

MAINTENANCE

MAINTENANCE

MAINTENANCE

TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.

APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.

DO NOT USE ABRASIVE CLEANERS.

!

WARNING

5.1

DO NOT CLEAN GLASS WHEN HOT! DO NOT USE
ABRASIVE CLEANERS TO CLEAN GLASS.

Buff lightly with a clean dry soft cloth. Clean both sides
of the glass after the fi rst 10 hours of operation with a
recommended fi replace glass cleaner. Thereafter clean
as required. If the glass is not kept clean permanent
discoloration and / or blemishes may result.

HOT GLASS WILL

CAUSE BURNS.

DO NOT TOUCH GLASS

UNTIL COOLED.

NEVER ALLOW CHILDREN

TO TOUCH GLASS.

!

WARNING

10.4 RESTRICTING VERTICAL VENTS - MODEL CDVS600

11.0 MAINTENANCE

11.1 CARE OF GLASS

77.3

Vertical installations may display a very active fl ame. If this appearance is not desirable, the vent exit must be
restricted using a restrictor vent kit. Refer to “ACCESORIES” in the “REPLACEMENTS” section for the ap-
propriate kit. This will reduce the velocity of the exhaust gases, slowing down the fl ame pattern and creating a
more traditional gentle fl ame appearance. Specifi c instructions are included with the kit.

Advertising