Warning – Continental Fireplaces CDVS600 User Manual

Page 5

Advertising
background image

5

W415-0791 / C / 04.18.12

2.1 DIMENSIONS

31

1

/

4

"

30

1

/

2

"

5

1

/

2

" 19

1

/

2

"

27"

17

7

/

8

"

4" DIA.

7" DIA.

24"

2.2 GENERAL

INSTRUCTIONS

THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER

to

conform with local codes. Installation practices vary from region to region and it is important to know the

specifi cs that apply to your area, for example in Massachusetts State:

This product must be installed by a licensed plumber or gas fi tter when installed within the commonwealth

of Massachusetts.

The appliance damper must be removed or welded in the open position prior to installation of a appliance

insert or gas log.

The appliance off valve must be a “T” handle gas cock.

• The

fl exible connector must not be longer than 36 inches.

A Carbon Monoxide detector is required in all rooms containing gas fi red appliances.

The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent

sealed combustion product.

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT,

WITH THE GLASS DOOR OPENED OR REMOVED.

PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.

PROVIDE ADEQUATE VENTILATION.

NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.

OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48” FROM THE

FRONT FACE OF THE APPLIANCE.

SURFACES AROUND AND ESPECIALLY ABOVE THE APPLIANCE CAN BECOME HOT. AVOID CONTACT

WHEN THE APPLIANCE IS OPERATING.

FIRE RISK. EXPLOSION HAZARD.

HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TESTING GAS

LINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE BEFORE PRESSURE

TESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG.

USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE.

USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING

COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.

!

WARNING