5.2 WALL AND CEILING PROTECTION

For optimum performance, it is recommended that all horizontal runs have a minimum 1/4" rise per foot when
venting. For safe and proper operation of the appliance, follow the venting instructions exactly.

This application occurs when venting through an exterior wall.
Having determined the correct height for the air terminal
location, cut and frame a hole in the exterior wall as
illustrated to accommodate the fi restop assembly.
Dry fi t the fi restop assembly before proceeding to
ensure the brackets on the rear surface fi t to the
inside surface of the horizontal framing.

The length of the vent shield may be cut shorter
for combustible walls that are less than 8 1/2” thick
but the vent shield must extend the full depth of the
combustible wall.

A. Apply a bead of caulking (not supplied) around the corner edge of

the inside surface of the fi restop assembly, fi t the fi restop

assembly to the hole and secure using the 4 screws (supplied in your

manual

baggie).

B. Once the vent pipe is installed in its fi nal position, apply high temperature sealant W573-0007 (not

supplied) between the pipe and the fi restop.

DETERMINE
THE
CORRECT
HEIGHT

CAULKING

FIRESTOP

SPACER

VENT

SHIELD

FINISHING
MATERIAL

20.2

!

WARNING

THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP.

TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE

RETURN FLANGE OF THE MOUNTING PLATE.

!

WARNING

DO NOT FILL THE SPACE BETWEEN THE VENT PIPE AND ENCLOSURE WITH ANY TYPE OF

MATERIAL. DO NOT PACK INSULATION OR COMBUSTIBLES BETWEEN CEILING FIRESTOPS.

ALWAYS MAINTAIN SPECIFIED CLEARANCES AROUND VENTING AND FIRESTOP SYSTEMS.

INSTALL WALL SHIELDS AND FIRESTOPS AS SPECIFIED. FAILURE TO KEEP INSULATION OR

OTHER MATERIALS AWAY FROM VENT PIPE MAY CAUSE FIRE.

70.1

5.2.1 HORIZONTAL INSTALLATION