5.2.4 VERTICAL AIR TERMINAL INSTALLATION - MODEL CDVS600

A.

Fasten the roof support to the roof using the screws provided. The

roof support is optional. In this case the venting is to be adequately

supported using either an alternate method suitable to the authority

having jurisdiction or the optional roof support.

B.

Stretch the inner fl ex pipe to the required length. Slip the

inner fl ex pipe a minimum of 2” over the inner pipe of the air

terminal connector and secure with 3 #8 screws. Seal using

a heavy bead of high temperature sealant W573-0007 (not

supplied).

C.

Repeat using the outer fl ex pipe, using a heavy bead of

high temperature sealant W573-0002 (not supplied).

D.

Thread the air terminal connector / vent pipe assembly down through

the roof. The air terminal must be positioned vertically and plumb.

Attach the air terminal connector to the roof support, ensuring that the

top of the air terminal is 16” above the highest point that it penetrates

the roof.

E.

Remove nails from the shingles, above and to the sides of the air

terminal connector. Place the fl ashing over the air terminal connector

leaving a min. 3/4” of the air terminal connector showing above

the top of the fl ashing. Slide the fl ashing underneath the sides and

upper edge of the shingles. Ensure that the air terminal connector

is properly centred within the fl ashing, giving a 3/4” margin all

around. Fasten to the roof. Do not nail through the lower portion

of the fl ashing. Make weather-tight by sealing with caulking. Where

possible, cover the sides and top edges of the fl ashing with roofi ng

material.

F.

Aligning the seams of the terminal and air terminal connector,

place the terminal over the air terminal connector making sure

the vent pipe goes into the hole in the terminal. Secure with the

three screws provided.

G.

Apply a heavy bead of weatherproof caulking 2” above the

fl ashing. Install the storm collar around the air terminal and slide

down to the caulking. Tighten to ensure that a weather-tight seal

between the air terminal and the collar is achieved.

H.

If more vent pipe needs to be used to reach the appliance see

“HORIZONTAL AIR TERMINAL INSTALLATION” section.

24.1

STORM COLLAR

FLASHING

CAULKING

WEATHER
SEALANT

2”

AIR INLET
BASE

ROOF SUPPORT

INNER FLEX PIPE

INNER PIPE

HIGH
TEMPERATURE
SEALANT

AIR

TERMINAL

CONNECTOR

OUTER FLEX PIPE

MAINTAIN A MINIMUM 2” SPACE BETWEEN THE AIR INLET BASE AND THE STORM COLLAR.

!