Led display board – Cybex 525AT Arc Trainer User Manual

Page 54

Advertising
background image

54

55

Cybex Service Manual

2. Pull the white (or red) heart rate wire through the second lowest front hole.
3. Connect the white (or red) heart rate wire to the tab on the front grip.
4. Connect the black heart rate wire to the tab on the back grip.

Do not pinch heart wires or allow contacts to touch each other when installing grips.

5. Install the five screws securing back grip to front grip using a Phillips screwdriver. Do not over

tighten grips.

Complete installation

1. Operate the unit at all levels to verify proper operation.
2. Hold the contact heart rate grips until a heart rate is displayed, typically less than thirty

seconds.

LED Display Board

Tools Required

Phillips screwdriver

ESD (Electrostatic Discharge) grounding strap.

Disconnect power source

1. Turn the main power switch to the off (O) position.
2. Unplug the power cord from the power outlet.

WARNING: Shock and electrocution hazard

Unplug unit and let sit 10 minutes before cleaning or performing maintenance

Electrical charge can remain in unit after unplugging

Keep water and liquids away from electrical parts

NOTICE:

Component damage

Wear an ESD grounding strap during this procedure. Connect ESD grounding strap to

frame bolts or unpainted metal of frame. If ESD grounding strap is not available, touch

frame bolts or unpainted metal of frame before handling any electronics.