Segment timer operation, Segment timer information, Section 5 – Daktronics All Sport 100 Contro User Manual

Page 23

Advertising
background image

Section 5:

Segment Timer Operation

Reference Drawing:

Insert; LL-2648 Segment Timer Code-06 ........................................................... Drawing A-274996

The All Sport 100 enters segment timing information
into the Daktronics BB-114, TI-2025 and TI-2026
displays using sport insert LL-2648, shown in Figure 7.
If this insert is lost or damaged, a copy of the insert
drawing, Drawing A-274996, can be used until a
replacement can be ordered.

Refer Section 3 for information on starting the console
and for instructions for use of the sport insert. Read the
Basic Operation material carefully to fully understand
the following operating instructions.

This section provides instructions for using the All
Sport 100 controller to program segment timing into
Daktronics BB-114, TI-2025 and TI-2026 displays. To run
the segment timer for these displays, enter Code 06 at
the Enter Code command.

5.1 Segment Timer Information

The segment timer is used to time events such as practice sessions. The operation of the
segment timer is determined by 40 segments of pre-programmed length. The segment timer
will count down starting at the segment number that is set as First Segment. When the first
segment is completed, the segment timer will count the Interval Time and proceed with the
next segment. The timer will continue counting segments until the segment number that is
set as Last Segment is counted down. It then will reset to the segment saved as the First
Segment
and will either begin counting down or pause for the <START> key to be pressed,
depending on the Auto Stop At Last Seg setting. To stop the timer after each segment is
completed, use the Auto Stop feature.

The First Segment and Last Segment values can be used to set up specific practice sessions.
For example, the practice session for one sport could be programmed to use segments 1-10,
while another might use segments 11-20. Set the First Segment and Last Segment values to
the desired segment numbers for the session and the console will count down each of the
segments in order, either stopping on the last segment or looping through included segments
again, based on the Auto Stop At Last Seg setting.

The default First Segment value is 1. The default value for the Last Segment is 40.

Figure 7: Segment Timer Insert LL-2648

Segment Timer Operation

19