Daktronics C44 User Manual

Page 21

Advertising
background image

New Track

2-7

Installation

Isolation Interface to Starters Box Interface Wiring

*Isolation Interface Drawing A-56252
**Start Line Interface Drawing A-72242

Isolation Interface to Start Line J-Box

Description

From (I/I)*

Cable

Specification

Wire Color

To (SLJB)**

Function

TB7-1 Red

TB3-1

LPSTAGEPCL-P

TB7-2 Black

TB3-7

LPSTAGEPCL-N

Pre-Stage
Left Lane

TB7-3

Beldon 8760

(Dak W-1117)

Shield No

Connection

Shield-N

TB7-4 Red

TB3-2

LSTAGEPCL-P

TB7-5 Black

TB3-7

LSTAGEPCL-N

Stage Left Lane

TB7-6

Beldon 8760

(Dak W-1117)

Shield No

Connection

Shield-N

TB7-7 Red

TB3-3

LGUARDPCL-P

TB7-8 Black

TB3-7

LGUARDPCL-N

Guard Left Lane

TB7-9

Beldon 8760

(Dak W-1117)

Shield No

Connection

Shield-N

TB1-1 Red

TB3-4

RPSTAGEPCL-P

TB1-2 Black

TB3-8

RPSTAGEPCL-N

Pre-Stage Right
Lane

TB1-3

Beldon 8760

(Dak W-1117)

Shield No

Connection

Shield-N

TB1-4 Red

TB3-5

RSTAGEPCL-P

TB1-5 Black

TB3-8

RSTAGEPCL-N

Stage Right Lane

TB1-6

Beldon 8760

(Dak W-1117)

Shield No

Connection

Shield-N

TB1-7 Red

TB3-6

RGUARDPCL-P

TB1-8 Black

TB3-8

RGUARDPCL-N

Guard Right Lane

TB1-9

Beldon 8760

(Dak W-1117)

Shield No

Connection

Shield-N

TB16-1 Red

TB1-1

SIG3-P

TB16-2 Black

TB1-2

SIG3-N

Tree Signal

TB16-3

Beldon 8760

(Dak W-1117)

Shield No

Connection

Shield-N

Refer to the Operational Check (Section 2.8) for connection and power up procedure.

*Isolation Interface
**Start Line Junction Box

Note: If field cabling for guard beam photocells is present, but guard beam
photocells are not used, do not connect unused guard beam cabling to the isolation
interface terminal blocks (TB7-7, TB7-8, TB7-9, LGUARDPCL, and TB1-7, TB1-8,
TB1-9, RGUARDPCL).

Description

Form (I/I)*

Cable

Specifications

Wire Color

To (SLI)**

Function

TB 13-1

Red

Trans +

Rec-P

TB 13-2

Black

Trans -

Rec-N

TB 13-3

Shield

Not Connected

Earth

TB 13-4

Green

Rec +

Trans-P

TB 13-5

White

Rec -

Trans-N

Isolation Interface/
Start line Interface

Communications

TB 13-6

Manhattan u4473

(Dak W-1234)

N.C. Not

Connected Earth