New Track

2-9

Installation

Intermediate One, 60'- Wiring between the isolation interface and the 60' photocell J-
boxes use multiple one pair shielded 18 awg cable. Plugs with clamping screws are used
for connection to the isolation interface. Refer to the following connection table to assist
in the installation. You may also reference the field cabling diagrams (Drawing B-
91012
and B-114631).

Intermediate Two, 330'-
Wiring between the isolation interface and the 330' photocell J-
boxes use multiple one pair shielded 18 awg cable. Plugs with clamping screws are used
for connection to the isolation interface. Refer to the following connection table to assist
in the installation. You may also reference the field cabling diagrams (Drawings B-
91012
and B-114631).

1/8 mile, 660' (Speed Trap)- Wiring between the isolation interface and the 660' speed
trap photocell J-boxes use multiple one pair shielded 18 awg cable. Plugs with clamping
screws are used for connection to the isolation interface. Refer to the following
connection table to assist in the installation. You may also reference the field cabling
diagrams (Drawings B-91012 and B-114631).

Intermediate 990'- Wiring between the isolation interface and the 990' photocell J-boxes
use multiple one pair shielded 18 awg cable. Plugs with clamping screws are used for
connection to the isolation interface. Refer to the following connection table to assist in
the installation. You may also reference the field cabling diagrams (Drawings B-91012
and B-114631 in Section 2.5).

1/4 mile, 1320' (Speed Trap)- Wiring between the isolation interface and the finish line
photocell J-boxes use multiple one pair shielded 18 awg cable. Plugs with clamping
screws are used for connection to the isolation interface. Refer to the following
connection table to assist you in the installation. You may also reference the field cabling
diagrams (Drawings B-56301 and B-114631).

Description

To (I/I)*

Cable

Specifications

Wire Color

From (Cell)**

Function

TB8-1 Red

J1-1

SIGNAL-P

TB8-2 Black

J1-3

GND

60

N Left Lane

TB8-3

Beldon 8760

(Dak W-1117)

Shield Not

Connected EARTH

TB2-1 Red

J1-1

SIGNAL-P

TB2-2 Black

J1-3

GND

60

N Right Lane

TB2-3

Beldon 8760

(Dak W-1117)

Shield Not

Connected EARTH

TB8-4 Red

J1-1

SIGNAL-P

TB8-5 Black

J1-3

GND

330

N Left Lane

TB8-6

Beldon 8760

(Dak W-1117)

Shield Not

Connected EARTH

TB2-4 Red

J1-1

SIGNAL-P

TB2-5 Black

J1-3

GND

330

N Right Lane

TB2-6

Beldon 8760

(Dak W-1117)

Shield Not

Connected EARTH

TB9-1 Red

J1-1

SIGNAL-P

TB9-2 Black

J1-3

GND

Start of Speed

Trap #1 Left Lane

(594

N)***

TB9-3

Beldon 8760

(Dak W-1117)

Shield Not

Connected EARTH

TB3-1 Red

J1-1

SIGNAL-P

TB3-2 Black

J1-3

GND

Start of Speed

Trap #1 Right

Lane (594

N)***

TB3-3

Beldon 8760

(Dak W-1117)

Shield Not

Connected EARTH

TB9-4 Red

J1-1

SIGNAL-P

TB9-5 Black

J1-3

GND

1/8 Mile Left

Lane (660

N)

TB9-6

Beldon 8760

(Dak W-1117)

Shield Not

Connected EARTH

Advertising