Maintenance &

4-3

Troubleshooting

Photocell Problems

Symptom/Condition

Possible Cause/Remedy

All

Check power to isolation interface

Check field and logic +5V LEDs on isolation
interface

All in one lane

Exchange photocell board

Swap PC board around to see if problem moves
to other side. (make sure to change dip switches)

Individual

Check to see if square lights on the monitor main
screen

Check red photocell LED on isolation interface

Realign photocell

Change photocell

Check photocell wiring for shorts or opens

Wire any unused photocells together at the
isolation interface.

Monitor Problems


Symptom/Condition


Possible cause/remedy

Nothing appears on monitor

Check monitor connection

Check power to C-44

Depress the reset switch

Check video port.

Isolation Interface Problems


Symptom/Condition


Possible cause/remedy


No LED’s lit

Check power to isolation interface

Check front panel fuse


No photocell LED’s lit

+5v field and +5v logic LED’s lit?

Check field wiring plugs

4.2

Maintenance

Always disconnect the system when it is not in use. Damage due to power surges and
lightning strikes can be significantly reduced by disconnection and storage of field control
equipment between events. Tower equipment should be powered down and if possible,
removed from signal wiring coming from the field.

Note: If field cabling is to remain connected to the isolation interface when not in use, the
isolation interface should be powered down via the front panel switch and must remain
plugged in to a three-conductor earth grounded outlet (to provide a discharge path to ground
for any voltage surges picked up by field cabling).

To prevent poor electrical contact due to corrosion on field control equipment connectors
(tree, photocells, start line electronics box, etc.), application of a silicon based lubricant
(Daktronics part # LU-1002) to terminals and connector pins is advised.

Tree Maintenance: All the electronics needed to operate the starting tree are located inside
the tree on one or two printed circuit boards. It may be interchanged with one from the spare
parts kit if any troubles occur.

Note: Before opening the tree, make sure that the power cord has been removed from its
outlet.