Tree problems, Printer problems, Display problems – Daktronics C44 User Manual

Page 50

Advertising
background image

4-2 Maintenance

&

Troubleshooting

Tree Problems

Symptom/Condition

Possible Cause/Remedy

Tree does not light at all

Check power and fuse to tree

Check power to isolation interface

Check bottom left corner of screen for SLCK

If SLCK is there, check power to starter’s box
interface

Check SBI to see if 3 LED’s are lit, Trans and Rec
leads from SBI to isolation interface may be
switched

Check SBI Trans and Rec LED’s on isolation
interface

Check communications cable which transmits data
from C-44 to SLEB

Bulb in tree not lit

Change bulb

Check socket and wiring

Change driver board

Bulb in tree stays lit

Change driver board

Tree Flickers

Check Grounding wires in Start line Box

Printer Problems

Symptom/Condition

Possible cause/remedy

Printer not working

Check to see if printer is enabled at C-44

Check power and connectors

Check to see if printer select light is lit

If Log printer

Check communications cable which sends data to
log printer

If E.T. printer

Check time slip printer interface LED’s

Check E.T. printer data LED on isolation interface

Check E.T. printer fault LED on isolation interface

Check communications cable which sends data to
E.T. printer

Display Problems


Symptom/Condition

Possible Cause/Remedy

No display at scoreboards

Enabled in C-44 Configuration Menu?

Check power to isolation interface and displays

Check display transmitter board In C-44,
(Drawing A-55998) which sends data to displays
via isolation interface.

Check for + 12VDC on signal input of driver.

Dial-ins not showing

In the scoreboard enable mode, was a Y placed in
the dial-in?

Is the F5 key being depressed?