Time slip printer/printer interface wiring – Daktronics C44 User Manual

Page 24

Advertising
background image

2-10 New

Track

Installation

TB3-4 Red

J1-1

SIGNAL-P

TB3-5 Black

J1-3

GND

1/8 Mile Right

Lane (660

N)

TB3-6

Beldon 8760

(Dak W-1117)

Shield Not

Connected EARTH

TB9-7 Red

J1-1

SIGNAL-P

TB9-8 Black

J1-3

GND

990

N Left Lane

TB9-9

Beldon 8760

(Dak W-1117)

Shield Not

Connected EARTH

TB3-7 Red

J1-1

SIGNAL-P

TB3-8 Black

J1-3

GND

990

N Right Lane

TB3-9

Beldon 8760

(Dak W-1117)

Shield Not

Connected EARTH

TB10-1 Red

J1-1

SIGNAL-P

TB10-2 Black

J1-3

GND

Start of Speed

Trap #2 Left Lane

(1254

N)***

TB10-3

Beldon 8760

(Dak W-1117)

Shield Not

Connected EARTH

TB4-1 Red

J1-1

SIGNAL-P

TB4-2 Black

J1-3

GND

Start of Speed

Trap #2 Right

Lane (1254

N)***

TB4-3

Beldon 8760

(Dak W-1117)

Shield Not

Connected EARTH

TB10-4 Red

J1-1

SIGNAL-P

TB10-5 Black

J1-3

GND

1/4 Mile Left

Lane (1320

N)

TB10-6

Beldon 8760

(Dak W-1117)

Shield Not

Connected EARTH

TB4-4 Red

J1-1

SIGNAL-P

TB4-5 Black

J1-3

GND

1/4 Mile Right

Lane (1320

N)

TB4-6

Beldon 8760

(Dak W-1117)

Shield Not

Connected EARTH

*Isolation Interface
**Intermediate/ Finish Line Photocell J-Box
*** Based on a 66 Ft Speed Trap

Time Slip Printer/Printer Interface Wiring

The Time Slip Printer is a 40 column Epson TM-4200 or an Epson LX300 (contact
Daktronics for other choices or models). The Time Slip Printer is then plugged into a
Printer Interface. The printer interface has a terminal block (TB1) to connect to the cable
coming from the isolation interface. Refer to the following table for connecting the cable
to the isolation interface. Use two, shielded 18 awg pair cables. You may also reference
the field cabling diagrams (Drawings B-91012 and B-114631).

Description

From (I/I)*

Cable

Specification

Wire Color

To (Printer

Interface)

Function

TB14-1 Red

TB1-4

ETFAULT-P

TB14-2 Black

TB1-5

ETFAULT-N

TB14-3

Beldon 8760

(Dak W-1117)

Shield Not

Connected Earth

TB14-4 Red

TB1-1

ETDATA-P

TB14-5 Black

TB1-2

ETDATA-N

Time Slip

Printer

TB14-6

Beldon 8760

(Dak W-1117)

Shield Not

Connected Earth

*Isolation Interface

Optional: Wiring Between the Isolation Interface and Scoreboards

Wiring between the isolation interface and the scoreboards/dial-in displays use multiple
one pair 18 awg shielded cables. Refer to the following wire connection table to assist in
the installation. You may also reference the field cabling diagrams (Drawings B-91012
and B-114631).

Advertising