Re-calibrating the scale – Digi-Star GT460 User Manual

Page 23

Advertising
background image

Re-Calibrating The Scale

Example Application 2: Grain cart with GT460 AutoLog

2

system is to

activate an alarm in tractor cab for 10 seconds to notify operator once
35,000 pounds is unloaded, so that the door can be closed. The operator
has a history of overloading the truck by 5000 pounds each time.
Set 477 ALP to ON. Set 406 RELAY to PRNOPA. Set 475 PAST to 10.0.
Set 442 to WEIGHT; TOLER to 5000. Press 35000 then ENTER to store
preset weight. Connect green DC Output wire to alarm +12VDC, black to
ground.

Operation: Start PTO, GT460 automatically loads 35,000 pound preset.
Open door to unload grain. Target weight is reached 5000 pounds early,
sounding alarm for operator to close the door. The preset is deactivated at
30,000 pounds to correct for overfill, and the data is logged when the PTO
is stopped.

RE-CALIBRATING THE SCALE

To re-calibrate the scale and make it even more accurate, document at
least 3 to 6 loads of varying sizes and measure the actual weight of all
loads on a certified scale.

• It must be assured that each truck is not losing grain in transit to a

certified scale.

• Weigh the truck immediately before unloading and immediately

after unloading to minimize errors due to changes in fuel etc.

In this example, six carts of grain are unloaded into four semi-trucks.
Example:

Cart Load A

51560

Cart Load B

33240

Cart Load C

17620

Cart Load D

50420

Cart Load E

38200

Cart Load F

12360

Total Indicator Weight 203400

Truckload #1

51920

Truckload #2

51320

Truckload #3

50720

Truckload #4

51070

Total Certified Weight 205030

D3804

GT460 AutoLog

2

Operators Manual

23

Advertising