Reading too high, Reading too low, Get your calibration number – Digi-Star GT460 User Manual

Page 24

Advertising
background image

Re-Calibrating The Scale

Reading Too High

If the Indicator is reading higher than the certified scale, then the
calibration number is high and should be decreased proportionally.

Reading Too Low

If the Indicator is reading lower than the certified scale, as shown in the
example above, then the calibration number is low and should be
increased proportionally.


Get your Calibration
Number








1. Enter 872

2. Press .

The calibration (CAL) number will

display. Example CAL = 24280.











Using the previous example your results would be:







1

2 4 2 8 0

P re s s h el p f or more
i nf orm at i on

TOTAL CERTIFIED WEIGHT

TOTAL INDICATOR WEIGHT

X CURRENT CAL NUMBER=NEW CAL NUMBER

205030
203400

X 24280 = 24475

2

24

GT460 AutoLog

2

Operators Manual

D3804