Re-Calibrating The Scale
Reading Too High
If the Indicator is reading higher than the certified scale, then the
calibration number is high and should be decreased proportionally.
Reading Too Low
If the Indicator is reading lower than the certified scale, as shown in the
example above, then the calibration number is low and should be
increased proportionally.
Get your Calibration
Number
1. Enter 872
2. Press .
The calibration (CAL) number will
display. Example CAL = 24280.
Using the previous example your results would be:
1
2 4 2 8 0
P re s s h el p f or more
i nf orm at i on
TOTAL CERTIFIED WEIGHT
TOTAL INDICATOR WEIGHT
X CURRENT CAL NUMBER=NEW CAL NUMBER
205030
203400
X 24280 = 24475
2
24
GT460 AutoLog
2
Operators Manual
D3804