Setting Options

D.A.N. 426 Settings:
Sets the state of the 12VDC output when PRESET, SEEDTD, PRNOPA,
or PREACT is selected in the D.A.N 406 menu. The SIG 12V setting will
configure the indicator to activate the 12VDC output when a preset weight
is reached. The normal state of the signal will be 0V. The SIG 0V setting
will maintain a 12VDC output when the preset is not active and will
switch to 0V when the preset is active. The default mode is SIG 12V.

D.A.N. 475 Settings:
Determines the behavior of the 12VDC output when D.A.N 406 is set to
PRESET, SEEDTD, PRNOPA, or PREACT. When a time between 0.1 to
99.9 seconds is entered, and D.A.N 406 is set to PRESET the indicator will
activate the 12VDC output when the preset is reached, delay for the
specified time, and set the output to 0VDC after the delay period. When
this is set to zero the 12VDC output will activate when the preset is
reached and stay active until the preset is cleared. The preset is cleared
when unloading stops. The default time is zero.

When unloading is stopped through the Start/Stop button or through
AutoLog

2

the 12VDC output deactivates.


D.A.N. 442 Settings:
This setting allows the 12VDC output to activate before the preset is
reached. It can be utilized in any D.A.N 406 mode, other than OFF. The
TOLER setting allows the operator to tune in the preset signal based on
the intended equipment. The TOLER can be set to WEIGHT or PERCNT.
This setting creates a window, based around the preset weight, and will
activate the 12VDC output, according to the selected D.A.N 406
configuration, when the measured weight is within that window.

D.A.N 476 Settings:
Used to change the normal view of the weight during the unloading
process. There are three modes, NET, GROSS, and LOAD. Default mode
is NET.

NET is the normal grain cart unloading method where the indicator counts
down from zero and displays negative weight throughout the unloading.

GROSS allows the display of the actual or gross weight of the indicator
and counts down from the total loaded weight.

LOAD displays the active preset weight and counts down from that value.
If more than the prescribed preset is unloaded, the display will begin to
count down from zero and show a negative number.