Rssmin), Rsstol), Rsstdy) – Digi-Star GT460 User Manual

Page 34

Advertising
background image

Setting Options

SETTING

[display]

D.A.N

NO.

OPTIONS [displayed]

BOLD=DEFAULT

DESCRIPTION

Preset Active
Signal
Timeout
(PAST)

475

Enter XX:XX

Time to continue preset
active signal after preset is
reached. See page 36.

Unload
Weight
Displayed
(UNWEDI)

476

NET
GROSS
LOAD

See page 36.

Auto Load
Preset
(ALP)

477

OFF,

STORED,

TRUCK, PARTCP

See page 37

MENU 5. CONTROL SETTINGS

RPM Start

/Stop
(RSSCTL)

531

ON

ON enables automatic
start/stop feature using
RPM sensor on PTO shaft.

RPM Stop
Speed
(RSSMIN)

532

300

Set to 20%-50% of PTO
operating RPMs. Stop is
activated using this value.

RPM Start
Tolerance
(RSSTOL)

533

100

Set to 10% of PTO
operating RPMs. Start is
activated using this value
added to DAN 532 (400)

RPM Start
Delay
(RSSTDY)

534

2

Time in seconds. Start is
activated when RPMs are
above DAN 532 + DAN 533
for this period.

RPM Stop
Delay
(RSSPDY)

535

2

Time in seconds. Stop is
activated when RPMs are
below DAN 532 for this
period.

CALIBRATION

Setup
Number

(

SETUP

)

871

Quick entry method selects
weigh method 1-4lbs, 5-
8kg, gain 1-9, display
counts 1-9 and capacity
*1000.

34

GT460 AutoLog

2

Operators Manual

D3804