Setting Options

SETTING

[display]

D.A.N

NO.

OPTIONS [displayed]

BOLD=DEFAULT

DESCRIPTION

Calibration
Number

(

CAL

)

872

Weight displayed at .4mV/V
for these load cells.

Preset Active Signal Functionality

Detailed below are different 12 VDC outputs available with the GT460.

D.A.N. 406 Settings:

• OFF – No 12VDC output will be activated.

• SETPNT – Set Point

o

Uses the weight threshold to activate and deactivate the

12VDC output.

• PRESET – Standard preset relay, lamp, and alarm functionality.

o

Uses the preset to determine the pulses of the light,

buzzer, and 12VDC output.

• SEEDTD – Seed Tender

o

During unloading the 12VDC output is activated and once

the preset is reached the light, buzzer, and the signal
deactivates. The light and buzzer also pulse when the pre-
alarm is active.

• PRNOPA – Preset No Pre Alarm

o

Uses the preset and pre alarm for the light and buzzer, but

the 12VDC output is only activated by the preset being
reached.

• PREACT – Preset Active Signal

o

During unloading the 12VDC output is active before the
preset weight is reached and the output deactivates when
the preset is reached. The light and buzzer are linked to
the pre-alarm and active until unloading is complete.