ONTIME: assigns alarm activation De-bounce Period to a specific alarm number. The alarm
event must be present at the start and at the end of the de-bounce Period before the alarm
status will be signalled using e-mail or syslog messaging (If enabled).
The period is specified in seconds and can take a value of 0 – 30,000. A value of 0 indicates
that there is no de-bounce period for this alarm type and a message will be generated
immediately the alarm event is detected.
OFFTIME: assigns an alarm removal De-bounce Period to a specific alarm number. The
alarm event must be absent at the start and at the end of the de-bounce period before the
alarm clearance will be signalled using e-mail or syslog messaging (if enabled).
The period is specified in seconds and can take a value of 0 – 30,000. A value of 0 indicates
that there is no de-bounce period for this alarm type and a message will be generated
immediately the alarm event is detected.
SYSLOG: enables or disables SYSLOG reporting for the selected alarm. Syslog settings are
on the IP setting page (section 5.3).
MAIL: enables or disables SMTP reporting for the selected alarm number. SMTP settings
are on the Email settings page (section 5.8).
MSG: Replaces the default text message ALARM <alarm_number> with the text entered
(maximum 40 characters). The status <on/off> is appended to the end of the text. If the MSG
value is blank, the default message is reinstated.

The message sent (for both mail and syslog reports), takes the form:

HOSTNAME COUNT TIME MSG ON/OFF

Where

HOSTNAME is from the Unit settings page (section 5.5).
COUNT is a volatile event counter (modulus 10000)
TIME is the event time and date from the unit's clock
MSG is the message set by the MSG field above. If no message has been set, the
default is "ALARM x" where x is the number shown against the alarms below.
ON/OFF is either the word ON or OFF according to the state of the alarm.


The History page displays a list of recent alarms (since last reset).
The "Edit" button on this page has no function.