9.13 LOGIC Module Command Line Syntax
Action
Verb
Parameters
Comment
1
2
3
SET
INPUT[1-
4]
DETECT
ON +
This command enables the generation of messages for the
auxiliary input given by the 2
nd
parameter when it goes to the
ON state .Default setting is NONE for all inputs.
OFF +
This command enables the generation of messages for the
auxiliary input given by the 2
nd
parameter when it goes to the
OFF State. Default setting is NONE for all inputs.
NONE
This command disables the generation of messages for the
auxiliary input given by the 2
nd
parameter. Default setting is
NONE for all inputs.
SENSE
[NORMAL|
INVERT]
This command inverts the sense of the logic input. If set to
NORMAL a logic 0 on the input is regarded as being the OFF
state. If Set to INVERT, a Logic 1 on the input is regarded as
being in the OFF state. Default is NORMAL
SYSLOG
[ON | OFF ]
This command enables or disables the sending of a logic input
change over SYSLOG. The default value is SYSLOGOFF
[ON | OFF ]
This command enables the sending of a logic input change
over SMTP. The default value is MAILOFF
MSG “text”
This command replaces the default text message Aux_in
ǻ<input_number> with the text entered as Parameter 3. The
text is delineated by Quote marks and is a maximum of 40
characters. The status <on/off> is appended to the end of the
text. If the “text” value is blank, the default message is
reinstated.
OUTPUT[
1-2]
GENERATE
OFF
This command sets the function of Volt Free Contact output 1
or 2 to be off. (Default State)
MUTE +
This command sets the function of Volt Free Contact Output 1
or 2 to indicate the output should be enabled when the audio is
muted by the user.
PULSE +
This command sets the function of Volt Free Contact output 1
or 2 to indicate if the output should be pulsed for the period set
by the associated timer.
RING +
This command sets the function of Volt Free Contact 1 or 2 to
be enabled when an incoming call is present and ringing , and
the on /off period will be as defined by the LOGIC SET
CADENCE commands
CALL +
This command sets the function of Volt Free Contact 1 or 2 to
be enabled when an outgoing call is present with an on /off
period which is as defined by the LOGIC SET CADENCE
commands
CONNECT +
This command set the function of the Volt Free Contact
outputs 1 or 2 to be enabled when a call is connected. If the
ANI feature is enabled, the volt free contact output is enabled
only when the call is connected and DTMF # has been
received.
HOOK +
This command sets the function of the Volt free contact 1 or 2
to show the status of the hook switch or ON/OFF/TOGGLE
button states. When the unit is in the off hook state the output
will be enabled. When the unit is in the on hook state the
output will be disabled.
INUSE +
This command sets the function of the volt free contact output
1 or 2 to be enabled when an incoming call arrives or when the
user goes off hook for an outgoing call, and disabled when the
call ends.
RINGCADEN
CE +
Causes the relay to operate at the same time as the ring tone
cadence.
PAGE +
Sets the output on when a call is present that has been
signalled as a PAGEMODE call (see UNIT page, section 5.5)
REGISTERED
+
Sets the output to pulse when the phone is registered with at
least one SIP server. Can be used as a “phone available”
indicator. The pulsing on /off periods are set by the CADENCE
field.
EMERGENCY
+
Sets the output to pulse whenever there is an outgoing call
present that has been initiated by an EMERGENCY button.
The pulsing on /off periods are set by the CADENCE field.
ON
This command sets the function of the volt free contact output
1 or 2 to be enabled permanently.
TIMER XX
This command sets the pulse timer value for Volt free contact
output 1 or 2 to be XX. XX is specified in seconds and can
have a value in the range 0 -3600. Default value is 3 seconds.
3XE