TROUBLESHOOTING:

POWER PROBLEMS

1).

Unit is totally inoperative.
a.

Check that units are receiving 120 VAC.

b.

Make sure that the power supply unit of the DG-12

II

is turned “ON” and the LED is

lighted.

c.

Push the Power Breaker[27] IN and release quickly to reset power on DG-12

II

.

2).

Talkback totally inoperative.

a.

Check fuse at rear of DG-MA. Unplug DG-MA from 120 Vac source before checking the

fuse.

3).

No Microphone power.

a.

Check for short on the DG-12

II

“A” terminals to “c” (ground). Remove short, If there is

still no + 15/VDC on the terminal, DG-12

II

power regulator maybe damaged.

AUDIO PROBLEMS

1).

Loud sound in one zone causes alarm in another zone.
a.

Microphone wires crossed between zones.

2).

Talkback from DG-MA occurs in wrong zone.

a.

Speaker wires crossed between zones.

3).

Speaker monitors zones, but headphone does not.
a.

Faulty headphone.

4).

Zone microphone inoperative.

a.

Check for + 15Vdc at microphone between terminals “A” and “C”.

b.

Temporarily plug in the connector of a known working microphone from another zone to

the DG-12

II

Mic/Talkback 5-pin Header[24] of the inoperative zone to confirm that the

circuitry of the DG-12

II

is operative and to confirm that the problem is in the remote

microphone or cabling.

5).

Zone speaker inoperative.

a.

Check wiring from DG-12

II

and remote speaker. Check color coding.

6).

No audio at speaker/headphone of DG-MA.

a.

Check that the plugs of cable connecting DG-12

II

Audio Out Jack[28] and DG-12

II

Input Jacks[41] on the DG-MA rear panel are making proper contact.

b.

Check if the jumper cable between Audio Input Jack[38] and Audio Output Jack[39] is

present. Jumper cable must be left in place when no recorder is connected.

c.

When used with a recorder interconnect cables. Replace recorder cables with factory

jumper at audio input/output jacks on the rear of DG-MA. If system works, recorder is
faulty.

7).

Sonalert inoperative
A.

Check position of Keyswitch[16].