Installation and operating instructions, Fig. 1 dg-12 front panel layout ii, Dg-12 – Louroe Electronics DG-12II User Manual

Page 7

Advertising
background image

PAGE 4 of 28

[16] Keyswitch

Turns ON power to the unit. Also
Turns ON the Sonalert Buzzer [4].

Switch operations:

Position 1- Power OFF
Position 2- Power ON
Position 3-Power and Sonalert Buzzer ON

[17] Audio Level Indicator

Shows the level of the audio of the zone in test, It contains 10 level
segments (7 green and 3 red) that illuminate and move up and down
the scale, depending upon the amount of signal it receives. Settings
should be made so that the level of the ambient sound on test does
not reach the red segments. The unit will go into alarm when the
audio reaches the last red segment.

[18] Alarm Delay Indicator

Indicates the length of the alarm delay setting.

[19] Alarm Delay Setting Pushbutton

Used to set the length of alarm delay. The switch can be pushed to
a maximum of 32 times. It must be pushed and released quickly.
The switch will go to the next step or more if not released
immediately.

[20] Night Sensitivity Setting Pushbutton Used to set the audio threshold sensitivity for nighttime. The

Day/Night Sensitivity Switch [9] must be in the UP position. The
switch can be pushed to a maximum of 32 times. Additional pushes
have no effect on the switch.

[21] Day Sensitivity Setting Pushbutton Used to set the audio threshold sensitivity for daytime. The

Day/Night Sensitivity Switch [9] must be in the Down position.
The switch can be pushed to a maximum of 32 times.

[22] Audio Alarm Output Jack

Provides DC output corresponding to the audio alarm level after the
filter network. Used to set and test the level of audio as seen at the
Audio Level Indicator [17]
. A test cable is provided to connect
between this jack and Audio Input Jack[6].

[23] Alarm Delay Output Jack

Provides output to the Alarm Delay Input Jack[8]. Used to set the
time delay feature and for checking the time delay setting, which is
variable between 0.1-3.2 seconds.

Fig. 1 DG-12 Front Panel Layout

II

16 17

18

19

20

21

22

23

POWER

SET-UP CONTROLS

MONITOR

TALKBACK

ZONES

E

L

OUROE

L E C TR O N IC S

TIME

DELAY

THRESHOLD
SENSITIVITY

SENSITIVITY

RESET

NON-ALARM

MONITOR

ALARM INPUT

ALARM DELAY INPUT

TIME RESET

TRIGGER

POWER

ALARM LEVEL

ALARM DELAY

DG-12

II

AUTO-RESET

OFF

ON

ON/AUDIO ALERT

DG_12II_6/11

LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406

TEL (818) 994-6498

FAX

994-6458

website: www.louroe.com e-mail: [email protected]

(818)

®

INSTALLATION AND OPERATING INSTRUCTIONS

Advertising
This manual is related to the following products: