APPLICATION:

The DG-12

II

“Duress Guard” audio alarm Base Station is a sound activated

12 zone audio surveillance system, which provides audio and visual alarms
when sound levels exceed the preset threshold, time duration and
frequency band in a given zone.

It is designed for life and property protection by monitoring areas of
possible crime or violence. When coupled to the DG-MA Monitor/Talkback
Amplifier, the operator may speak and listen to any or all surveillance
zones, as selected on the front panel. An audio mixer such as Louroe's
MLA-6 may be used to expand the area of coverage per zone. Up to 6
microphones per zone may be used.

Provisions for audio output to a recorder and alarm relay closures for other
equipment are available at the DG-12

II

rear panel. A tester for alarm delay

and audio is built into the DG-12

II

. The DG-12

II

will work with all Louroe

microphones and speakers. Two-way talk/listen is accomplished with the
addition of a DG-MA Monitor/Talkback Amplifier.

QUICK REFERENCE:

Wiring Requirements:

If using microphones for one-way / listen-only:

2 Conductor shielded cable, 22-gauge with a 24-gauge drain wire.

West Penn 452 or equivalent

NOTE: Unshielded cable is not recommended for

microphone connections.

If using speaker/microphones for two-way listen/talkback:

4 Conductor (all within the same jacket):

Microphone Connection: 2 Conductor shielded, 20-gauge with a

22-gauge drain wire.

Speaker Connection:

2 Conductor unshielded, 18-gauge

West Penn 356 or equivalent

PAGE 1 of 28

DG_12II_6/11

LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406

TEL (818) 994-6498

FAX

994-6458

website: www.louroe.com e-mail: [email protected]

(818)

®

INSTALLATION AND OPERATING INSTRUCTIONS