3 how to use the omr marks, Gate 1, gate 2, Sequence 1 - 2 – MBM Corporation 49 User Manual

Page 25: End of set (e.o.s), Parity

Advertising
background image

T10114

Jan 2001

Sheet Feeder Model 49 Operator Manual

8-2

Mark Structure

Gate 1
Gate 2
E. O. S.
Parity
Seq. 1
Seq. 2

1 2 3 4 5 6 7 8

The example below illustrates a set containing eight sheet.

Gate 1, Gate 2

The Gate 1 and Gate 2 act as start - reading - marks. Each mark
sequense must always include the two Gate marks. If not, the sheet
will be detected as blank.

Sequence 1 - 2

The “Seq1” & “Seq2” marks are needed for the OMR reader to detect
that the sheets in a set are fed in the right order. The sequence is: No
marks, S1 mark, S2 mark, S1 and S2 mark, no mark and so on. Each
new group shall start with the sequence number 0 (no marks), see
examples below.

End Of Set (E.O.S)

To indicate the last sheet in a set, an ”End Of Set” mark is required.

Parity

There must allways be an even number of marks on each sheet. When
needed, add the parity mark.

Page

The example below illustrates a set containing five sheets.

Page

1 2 3 4 5

G1
G2
EOS

S1

P

S2

8.3 How to Use the OMR Marks