Microcom 326M User Guide User Manual

Page 30

Advertising
background image

Printer Modes

Chapter 4

18

326M User’s Guide

Byte Mode

Responses

(ASCII Hex)

Text and Verbose Mode Responses

Definition

0xE2

>SWITCH 1 ACTUATED<

Switch 1 has been actuated.

0xE3

>SWITCH 2 ACTUATED>

Switch 2 has been actuated.

0xE4

>TOF SWITCH ACTUATED<

The TOF switch has been

actuated.

0xF0

>FIELD OFF IMAGE<

An image placement

coordinates exceed the print

head or form size.

0xF2

>GRAPHIC TOO LARGE<

The sent graphic exceeds the

available memory.

0xFF

>POWERED DOWN<

The printer’s power has been

removed.

Table 7

Enquiry Responses


4.2.2

Fatal Error Responses

Fatal error responses are enquiry responses that halt the printer’s current operation and
cause the indicator light or LED to flash RED in color. A fatal error condition persists until
the condition causing the error is removed and the error is cleared. These enquiry
responses are sent from the printer to the host, when the appropriate condition occurs, by
issuing the “Ctrl+E” (^E) combination or by issuing the queued “^D327)1” command. The
printer may be configured to automatically reports errors and status messages by using the
^D72x series commands. The following sections provide further explanations of the various
fatal error responses. Refer to the ^D550) command regarding the types of enquiry
response sets.

NOTE: The following section titles are the responses that the printer will generate once the

associating condition occurs and the printer processes an enquiry command. The first

response (between and including the “>” and “<” characters) is generated if text and

verbose responses have been enabled using the ^D550) command. The ASCII hex value
listed between the parenthesis characters, indicate the enquiry response if byte mode has

been enabled.



4.2.2.1

>STOCK OUT< (01)

The “>STOCK OUT<” error response is generated when the printer runs out of stock or
media while in text and verbose modes. If the printer is configured for byte responses, the
code ASCII 0x01 will be issued from the printer in response to an enquiry command.


4.2.2.2

>STOCK OVERADVANCED< (02)

This error response is typically generated when the printer has an excess amount of media
feed out of the printer and a Top-of-Form operation is executed. If the printer is configured

Advertising