13-2. stp configuration – Microsens MS453522M User Manual

Page 105

Advertising
background image

MICROSENS 8 Port Gigabit Ethernet Switch

User’s Manual

100


3-13-2. STP Configuration

The STP, Spanning Tree Protocol, actually includes RSTP. In the Spanning Tree

Configuration, there are six

parameters open for the user to configure as

user’s idea. Each parameter description is listed below.

Function name:

STP Configuration

Function description:

User can set the following Spanning Tree parameters to control STP function enable/disable,
select mode RSTP/STP and affect STP state machine behavior to send BPDU in this switch.
The default setting of Spanning Tree Protocol is “Disable”.

Parameter description:

Spanning Tree Protocol:

Set 802.1W Rapid STP function Enable / Disable. Default is “Disable”

Bridge Priority:

The lower the bridge priority is, the higher priority it has. Usually, the bridge with the
highest bridge priority is the root. If you want to have the MICROSENS as root bridge,
you can set this value lower than that of bridge in the LAN. The valid value is 0 ~
61440. The default is 32768.

Hello Time:

Hello Time is used to determine the periodic time to send normal BPDU from
designated ports among bridges. It decides how long a bridge should send this
message to other bridge to tell I am alive. When the MICROSENS is the root bridge of
the LAN, for example, all other bridges will use the hello time assigned by this switch
to communicate with each other. The valid value is 1 ~ 10 in unit of second.

Default is 2 seconds.

Max. Age:

When the MICROSENS is the root bridge, the whole LAN will apply this figure set by
this switch as their maximum age time. When a bridge received a BPDU originated
from the root bridge and if the message age conveyed in the BPDU exceeds the Max.
Age of the root bridge, the bridge will treat the root bridge malfunctioned and issue
a Topology Change Notification (TCN) BPDU to all other bridges. All bridges in the
LAN will re-calculate and determine who the root bridge is. The valid value of Max.
Age is 6 ~ 40 seconds. Default is 20 seconds.

Advertising