2-3. simple counter – Microsens MS453522M User Manual

Page 58

Advertising
background image

MICROSENS 8 Port Gigabit Ethernet Switch

User’s Manual

53


3-2-3. Simple Counter

The function of Simple Counter collects any information and provides the counting about

the traffic of the port, no matter the packet is good or bad.

In the Fig. 3-13, the window can show all ports’ counter information at the same time.

Each data field has 20-digit long. If the counting is overflow, the counter will be reset and
restart counting. The data is updated every time interval defined by the user. The valid range is
3 to 10 seconds. The Refresh Interval is used to set the update frequency. Default update time is
3 seconds.

Fig. 3-13


Function name:

Simple Counter

Function description:

Display the summary counting of each port’s traffic, including Tx Byte, Rx Byte, Tx Packet,
Rx Packet, Tx Collision and Rx Error Packet.

Parameters description:

Tx Byte:

Total transmitted bytes.

Rx Byte:

Total received bytes.

Tx Packet:

The counting number of the packet transmitted.

Rx Packet:

The counting number of the packet received.

Tx Collision:

Number of collisions transmitting frames experienced.

Rx Error Packet:

Number of bad packets received.