Microsens MS453522M User Manual

Page 181

Advertising
background image

MICROSENS 8 Port Gigabit Ethernet Switch

User’s Manual

176



set timer

Syntax:
set timer <range> <join> <leave> <leaveall>
Description:
To set gvrp join time, leave time, and leaveall time for each port.
Argument:
<range> : port range, syntax 1,5-7, available from 1 to 8
<join>: join timer, available from 20 to 100
<leave>: leave timer, available from 60 to 300
<leaveall>: leaveall timer, available from 1000 to 5000
Leave Time must equal double Join Time at least.
Possible value:
<range> : 1 to 8
<join>: 20 to 100
<leave>: 60 to 300
<leaveall>: 1000 to 5000
Example:
MICROSENS(gvrp)# set timer 2-8 25 80 2000


show config

Syntax:
show config
Description:
To display the gvrp configuration.
Argument:
None.
Possible value:
None.
Example:

MICROSENS(gvrp)# show config
GVRP state: Enable

Port

Join Time

Leave Time

LeaveAll Time Applicant

Registrar Restricted

-------------------------------------------------------------------------------------------------------------------------------------
1

20

60

1000

Normal

Normal

Disable

2

25

80

2000

Normal

Normal

Disable

3

25

80

2000

Normal

Normal

Disable

4

25

80

2000

Normal

Normal

Disable

5

25

80

2000

Normal

Normal

Disable

6

25

80

2000

Normal

Normal

Disable

7

25

80

2000

Normal

Normal

Disable

8

25

80

2000

Normal

Normal

Disable

Advertising