Microsens MS453522M User Manual

Page 17

Advertising
background image

MICROSENS 8 Port Gigabit Ethernet Switch

User’s Manual

12

2-1-3-1. Cabling Requirements for TP Ports

⇒ For Fast Ethernet TP network connection

⎯ The grade of the cable must be Cat. 5 or Cat. 5e with a maximum length of 100 meters.

⇒ Gigabit Ethernet TP network connection

⎯ The grade of the cable must be Cat. 5 or Cat. 5e with a maximum length of 100 meters.

Cat. 5e is recommended.

2-1-3-2. Cabling Requirements for 1000SX/LX SFP Module

It is more complex and comprehensive contrast to TP cabling in the fiber media. Basically,

there are two categories of fiber, multi mode (MM) and single mode (SM). The later is
categorized into several classes by the distance it supports. They are SX, LX, LHX, XD, and ZX.
From the viewpoint of connector type, there mainly are LC and BIDI LC.

Gigabit Fiber with multi-mode LC SFP module

Gigabit Fiber with single-mode LC SFP module

Gigabit Fiber with BiDi LC 1310nm SFP module

Gigabit Fiber with BiDi LC 1550nm SFP module

The following table lists the types of fiber that we support and those else not listed here

are available upon request.

Multi-mode Fiber Cable and Modal Bandwidth

Multi-mode 62.5/125

μm Multi-mode

50/125

μm

Modal

Bandwidth

Distance

Modal
Bandwidth

Distance

160MHz-Km

220m

400MHz-Km

500m

IEEE 802.3z
Gigabit Ethernet
1000SX 850nm

200MHz-Km

275m

500MHz-Km

550m

Single-mode Fiber 9/125

μm

Single-mode transceiver 1310nm 10Km

1000Base-
LX/LHX/XD/ZX

Single-mode transceiver 1550nm 30, 50Km

TX(Transmit) 1310nm

Single-Mode

*20Km

RX(Receive) 1550nm

TX(Transmit) 1550nm

1000Base-LX
Single Fiber
(BIDI LC)

Single-Mode

*20Km

RX(Receive) 1310nm

Table2-1

Advertising