Microsens MS453522M User Manual

Page 26

Advertising
background image

MICROSENS 8 Port Gigabit Ethernet Switch

User’s Manual

21

With the classful addressing, it divides IP address into three classes, class A, class B and

class C. The rest of IP addresses are for multicast and broadcast. The bit length of the network
prefix is the same as that of the subnet mask and is denoted as IP address/X, for example,
192.168.1.0/24. Each class has its address range described below.

Class A:

Address is less than 126.255.255.255. There are a total of 126 networks can be defined

because the address 0.0.0.0 is reserved for default route and 127.0.0.0/8 is reserved for loopback
function.

0

Class B:

IP address range between 128.0.0.0 and 191.255.255.255. Each class B network has a 16-bit

network prefix followed 16-bit host address. There are 16,384 (2^14)/16 networks able to be
defined with a maximum of 65534 (2^16 –2) hosts per network.

10

Class C:

IP address range between 192.0.0.0 and 223.255.255.255. Each class C network has a 24-bit

network prefix followed 8-bit host address. There are 2,097,152 (2^21)/24 networks able to be
defined with a maximum of 254 (2^8 –2) hosts per network.

110

Bit # 0 1 7 8 31

Network address Host address

Bit # 01 2 15 16 31

Network address Host address

Bit # 0 1 2 3 23 24 31

Network address Host address