set ntp

Syntax:
set ntp <ip> <timezone>
Description:
To set up the current time via NTP server.
Argument:
<ip>: ntp server ip address or domain name
<timezone>: time zone (GMT), range: -12 to +13
Possible value:
<timezone>: -12,-11…,0,1…,13
Example:
MICROSENS(time)# set ntp clock.via.net 8
Synchronizing...(1)
Synchronization success


show

Syntax:
show
Description:
To show the time configuration, including “Current Time”, “NTP Server”,” Timezone”,
” Daylight Saving”,” Daylight Saving Start” and “Daylight Saving End”
Argument:
None.
Possible value:
None.
Example:
MICROSENS(time)# show
Current Time

: Thu Thu 14 15:04:03 2005

NTP

Server

:

209.81.9.7

Timezone

:

GMT+8:00

Day light Saving

: 0 Hours

Day light Saving Start : Mth: 1 Day: 1 Hour: 0
Day light Saving End : Mth: 1 Day: 1 Hour: 0