4. Operation

4-3

4.1.2

Indicator lamp

Turn the starter switch to “ON” position. Then the lamp will go on.

Item Contents Measures

Monitor

GLOW

Press starter switch “ON” and

the lamp goes on and after pre-

heating is finished, the lamp will

be off.


AUTO IDLE

AUTO IDLE Switch “ON” and

then lamp goes on.

When some little trouble occurs during operation, the lamp will go on.
When the warning lamp goes on, take appropriate measures to recover the situation swiftly.

Item Contents Measures

Monitor

CHARGE

Lamp goes on when alternator is
not charging.

Check wiring.
Check alterna-
tor.

COMP.
AIR FILTER

ENG.
AIR FILTER

Lamp goes on when air filter gets

clogged and suction resistance in-
creases.

Actuating resistance is more than

6.2kPa.


Clean
Replace


The compressor stops when the emergency stop lamp goes on.

Be sure to follow the measures shown below before starting the unit again.

Item Contents

Measures

Monitor

LOW FUEL
LEVEL

When fuel level in fuel tank drops
and it becomes necessary to
replenish fuel, the lamp goes on.

See
“Troubleshooting”

FUEL FILTER
DRAIN

When fuel filter gets clogged with
condensate inside,the lamp goes on. Drain condensate

DISCHRGE

TEMP.

Lamp goes on when the air tem-

perature at the outlet of the

air-end reaches the set tem-

perature of 248°F (120°C).

WATER TEMP.

Lamp goes on when coolant tem-
perature reaches 230°F
(110°C).

ENG.
OIL PRESS.

Lamp goes on when engine oil

pressure drops.

The function pressure is below

0.06MPa.

See
“Troubleshooting”

Indicator lamp

Warning lamp

Emergency stop

lamp

Advertising