Operation – MMD Equipment 185S-6C1 User Manual

Page 32

Advertising
background image

4. Operation

4-14


4.4.4 Gauge Indication while Operating

Minimum discharge air pressure is 0.39MPa during load operation.

Continuing equipment operation at a lower pressure than the above pressure may cause overheating,
since it affects the separation of lubricating oil inside the oil separator and reduces the oil flow to the
compressor air-end, resulting in temperature rise.

Be sure to check at times to see if gauges or each component of the unit are properly working, or if
there is any air-leak, oil-leak, water-leak or fuel-leak etc.

During normal operation, each indication of instruments is shown in the table below. Refer to the
table for daily checks.

The above table gives standard values. They may vary slightly depending on the operating condi-
tions and other factors.

Emergency stop Lamp

Protection

device

Discharge

temperature

Water

temperature

Engine oil

pressure

Low fuel

level

Fuel filter

drain

Monitor

Starting

Starter

switch set

to “RUN”

position

n

OFF

n

OFF

n

OFF

n

OFF

n

OFF

In Operation

n

OFF

Warning Lamp

Indicator lamp

Protection

device

Charge

Compressor

air filter

Engine

air filter

Glow

Auto

idle

Monitor

AUTO

IDLE

Starting

Starter

switch set

to “RUN”

position

ON

n

OFF

n

OFF

n

OFF

n

OFF

In Operation

n

OFF

Note:*: Lamp goes off after preheating completed.

Discharge

air

pressure gauge

Full load

72.5-100 psi

(5-6.9 bar)

Unload

104-131 psi

(7.2-9.0 bar)

In

operat

ion

Auto idle

43.5-58 psi

(3.0-4.0 bar)