5. Periodic Inspection/Maintenance

5-1

5.1 Important Items at Periodic Inspection and Maintenance or after

Maintenance

The manual shows proper interval for periodic inspection and maintenance under normally op-
erating conditions. Inspection and maintenance should be performed more often under extremely
harsh conditions.

Remove the starter key from the starter switch before starting
inspection, and hang up a “Now Checking and under
Maintenance” tag where it can be easily seen. The checker
must keep the key during checking and maintenance.

Remove the negative (–) side cable from the battery.
If the above procedure is neglected, and another person starts
operating the machine during check or maintenance, it could
cause serious injury.

Use tools appropriate for the inspection and maintenance. Any
makeshift or improper tools could cause unexpectedly injury by
their slippage.



Be sure to perform oil change basically according to the
specified interval. But if such oil is found much more
contaminated before the interval, change the oil even
before the specified period comes. In doing so, replace
the oil completely and use our recommended oil.

Be sure to perform following periodic inspection and
maintenance:
1. Check and change compressor oil
2. Change oil separator

Never mix the oil of different brands, or the mixed oil may
deteriorate the oil quality.



Hang a “Now Checking and under Maintenance” tag

Prevention of oil separator from catching fire

SY001

A070194

2

1