Periodic inspection/maintenance – MMD Equipment 185S-6C1 User Manual

Page 49

Advertising
background image

5. Periodic Inspection/Maintenance

5-12


5.5.13 Change Coolant

[1,000 hours or every 2 years]


Be sure to stop the machine and allow time to cool. Then
loosen the radiator cap one notch. After the coolant water
is sufficiently cooled and the inner pressure is released,
take the cap off.
If this procedure is neglected, the inner pressure can blow
off the cap. Steam jetting out of the radiator could result in
causing scalding. Follow this procedure under all circum-
stances.

LLC (Antifreeze) is a toxic material.

When a person has drunk LLC (Antifreeze) by accident, make him vomit and see a doctor im-
mediately.

When a person gets LLC (Antifreeze) in his eyes, wash the eyes with clean running water and
make him see a doctor immediately.

When LLC (Antifreeze) is stored, put it in a container with an indication saying “LLC (Antifreeze)
inside” and seal it up, then keep it in a place away from children.

Beware of flames.

<Procedure>

To drain coolant, first unfasten and take off

the cap“1”of the radiator, open the drain
valve“2”.

Loosen the drain plug“3”provided on engine

to drain engine.

When the drainage has been completed,

fasten drain valve “2”drain plug“3”again
and fill coolant into the radiator through its
filler port.

After changing the coolant, operate the

machine for 2 to 3 minutes at the unloaded
condition and stop it. Then check the coolant
level again, and replenish if it is short.












1

2

3

W005

Caution in filling or discharging engine oil

A070188

The opposite of the

maintenance side.

Advertising