4.3.6 Drain fuel tank

Opening the drain valve“2”fitted under the fuel

tank“1”, drain the condensate from the tank.

When completely drained, firmly close the drain

valve“2”.

Drain the condensate in container“3”,and then

dispose of condensate according to the designated
regulations.







4.3.7 Check fuel filter(sedimenter built-in type) for condensate

Whenever interval of periodical replacement of

Condensate in fuel filter comes or the warning lamp
Drain condensate accumulated goes on,in the filter.

<Procedures>

Loosen drain valve “1” and then drain the condensed water

accumulated in the filter.

Make sure to tighten the drain valve “1” securely, after

draining the condensate.

Finally carry out air bleeding in fuel system, pushing the

priming pump “2” up and down. continue this operation
till the pump moves heavily.

Drain the condensate in container, and then dispose of

condensate according to the designated regulations.