Periodic inspection/maintenance – MMD Equipment 185S-6C1 User Manual

Page 53

Advertising
background image

5. Periodic Inspection/Maintenance

5-16


5.5.23 Check Pressure Control Valve O-Ring and Piston

Disassemble and clean the component, and check O-ring“1”,“2” and the piston“4” shown in

5.5.22 Then, replace O-ring“1”,“2” and rubber on the piston“4”, if they are hardened.

(See 5.4)

Ask your nearest dealer for its replacement.

After replacement, run the machine to check its function (See 5.5.22), air-leak or any disorder.

5.5.24 Change Radiator Hoses

[3,000 hours or every 3 years ]

When any crack or wear is found on the hoses, change it even before the scheduled time.

Replacement of the radiator hoses requires expert technical knowledge. So contact directly us or

distributor.

Advertising