Operation – MMD Equipment 185S-6C2 User Manual

Page 26

Advertising
background image

4.Operation

4-7

H000039

4.3.6 Drain fuel tank



Opening the drain valve“2”fitted under the fuel

tank“1”, drain the condensate from the tank.



When completely drained, firmly close the drain
valve“2”.



Drain the condensate in container“3”,and then
dispose of condensate according to the designated
regulations.


4.3.7 Check sedimenter for condensate

When red float“2”under element“1”in fuel filter
is raised up to upper level, drain water.

Draining procedure>

Turn fuel selector valve“3”to“OFF”position.

Loosen the drain valve“4”and drain out

condensed water inside.

Make sure to tighten the drain valve“4”

securely, after draining the condensate.



Drain the condensate in container“5”,and

then dispose of condensate according to the
designated regulations.













4.3.8 Check wiring of each part

Check each wiring for any loose connection, damage to insulating sheathed portion, disconnection,
and short-circuit.


4.3.9 Check piping of each part

Check each piping for any loose connection and also check each hose and pipe for any tear and
leaks.

3

A090228-3

3

1

2

4

5

ON

OFF

2

1

Advertising