Maintenance – MMD Equipment 185S-6C2 User Manual

Page 53

Advertising
background image

6. Maintenance

6-2

A030594

A030595

6.1.1 Charge battery



Be sure to read the operation manual of the battery charger
to know if it is applicable, before using it.



Disconnect the cable between battery and the unit, and
charge the battery with a 12V battery charger. Do not charge
two batteries at the same time.



Be sure not to connect (+) and (–) terminals backwards.


6.1.2 How to use booster cable




If a booster cable has to be used or when cables are connected at battery replacement, be careful not to

connect (+) and (–) terminals backwards. Such a wrong-connection will cause spark and damage each

component.

<Procedure for using a booster cable>

Stop the engine.

Connect one end of the (+) cable to the (+) terminal of
the machine battery.

Connect the other end of the (+) cable to the (+)
terminal of the external battery.

Connect one end of the (–) cable to the (–) terminal of
the external battery.

Connect the other end of the (–) cable to the engine
block of the machine.

Start up the engine.

Disconnect the booster cable by following the
procedure back in the reverse order.

Connect to the engine block

Battery of the unit

External battery (12V)

Do not reverse the cable connection

Advertising