Operation – MMD Equipment 185S-6C2 User Manual

Page 30

Advertising
background image

4.Operation

4-11

4.4.4 Gauge Indication while operating



Minimum discharge air pressure is 58psi (4bar) during operation.



Continuing equipment operation at a lower pressure than the above pressure may cause overheating,
since it affects the separation of lubricating oil inside the oil separator and reduces the oil flow to the
compressor air-end, resulting in temperature rise.



Be sure to check at times to see if gauges or each component of the unit are properly working, or if

there is any air-leak, oil-leak, water-leak or fuel-leak etc.



During normal operation, each indication of instruments is shown in the table below. Refer to the

table for daily checks.



The above table gives standard values. They may vary slightly depending on the operating

conditions and other factors.

Indicator lamp

Protection

device

GLOW CHARGE

Auto

idle

Monitor

AUTO IDLE

Starting

Starter

switch set

to “RUN”

position

OFF

0N

OFF

In operation

OFF

This lamp will be OFF in 0 to 20 seconds, (varying upon ambient temperature.)

Discharge

pressure gauge

Full load

58 to 100 psi

(4 to 6.9 bar)

No load

(Unload)

104 to 131 psi

(7.2 to 9.0 bar)

In op

erat

io

n

At purge control

(AUTO IDLE)

58 to 73 psi

(4.0 to 5.0 bar)